Call us
08045476244
Technical Specifications
|
Power supply |
Voltage range |
88 - 300 VDC / VAC, 42.5 to 67.5 Hz (optional 36 - 72 VDC) |
|
|
Power |
20 VA |
|
|
Auxiliary output |
DC output 12 VDC at 750 mA |
|
MMI |
Display |
Backlit LCD, 114 x 49mm - 240 x 80 dots |
|
|
Keypad |
7 button membrane keypad |
|
|
Status |
9 LEDs (healthy, alarm, trigger, clock sync, comms, status) |
|
Line modules |
TWS FL-1 |
Fixed format with one line module |
|
|
TWS FL-8 |
2 line modules expandable to 8 in steps of 2 |
|
|
Channels |
3 (one per phase) from external linear couplers - 12 bit ADC |
|
|
Gain |
Programmable full scale deflection |
|
|
Triggering |
Programmable threshold level |
|
|
Sample rate |
20 MHz, 10 MHz, 5 MHz, 2.5 MHz or 1.25 MHz |
|
|
Diagnostics |
Automatic test of channel front end to prove operation |
|
Digital inputs |
2 per line module |
Wide ranging input from 48 to 250 VDC - selectable debounce |
|
Storage |
CompactFlash |
4 GB allowing storage of 2100 records from 8 line modules at a sampling rate of 2.5 MHz (option for 8GB on request) |
|
|
Modes |
Selectable locked or cyclic buffer |
|
Clock |
Internal |
Synchronized by internal GPS module (master) or via NTP over LAN and a 1 pps (slave |
|
|
Accuracy |
Master 100 ns. Slave 1 microsecond |
|
|
Output |
IRIG-B out to synchronize other IEDs |
|
GPS antenna |
Lead length |
10 meters [33 feet] (optional extension leads available) |
|
|
Mounting |
Via 25mm [1 inch] pipe mast |
|
Comms |
Modem (optional) |
Internal PSTN (V.90) modem (optional on COM 4) |
|
|
Ethernet port |
2 x 100 Mbits - one RJ45 for local connection at the front and one RJ45 (with option for fiber) on the rear port |
|
|
USB |
One port to facilitate firmware upgrade and manual download of data |
|
|
Serial |
3 x RS 232 provided (one front panel, two on rear). 1 x RS 485 on rear panel |
|
Alarms |
4 provided |
1 (normally closed) for system healthy 3 (normally open) for lost lock, trigger and high priority trigger and fixed buffer 80% full |
|
Configuration |
iQ+ Master station |
Edit configuration and view diagnostics |
|
|
Web page |
Access via browser - edit settings, manual trigger, view last waveform |
|
Environmental |
Temperature |
Operating: -5 to +50 Degree C [23 to 122 Degree F]. Storage: -30 to +70 Degree C [-22 to 158 Degree F] |
|
|
Humidity |
0 to 95% non-condensing |
|
Immunity |
IEEE, EU and IEC |
Conforms to relevant specifications for monitoring / control equipment in HV substations |
|
Mechanical |
Enclosure |
IP 41, 19 rack-mountable |
|
|
TWS FL-8 |
3U device - H x W x D: 132.5 mm [5.2] 487 mm [19.2] x 362.2 mm [14.3] Weight - 11 kg [24.2 lbs]. |
|
|
TWS FL-1 |
2U device - H x W x D: 90 mm [3.25] x 487 mm [19.2] x 362.2 mm [14.3] |

Price:
Minimum Order Quantity : 1 Unit
Usage : Industrial
Measuring Range : 080 km
Response Time : 3 s
Display Type : Digital LCD
Control Mode : Manual/Automatic
Usage : Electrical Cable Fault Location
Measuring Range : Short to Long Cable Faults
Response Time : <2 seconds
Display Type : HighResolution LCD Display
Control Mode : Microprocessor Controlled